Answers are grounded in this paper and cite their sources.
Purpose: To investigate the best parameter between cross-sectional dimensions and body weight in pediatric low dose abdominal CT. Materials and Methods: One hundred and thirty six children consecutively underwent weight-based abdominal CT.The subjects consisted of group 1 (79 children, weight range 10.0-19.9kg) and group 2 (57 children, weight range 20.0-39.9kg).Abdominal cross-sectional dimensions including circumference, area, anteroposterior diameters and transverse diameters were calculated.Image noise (standard deviation of CT density) was measured by placing a region of interest in the posterior segment of the right hepatic lobe on a CT image at the celiac axis.The measured image noise was correlated with the cross-sectional abdominal dimensions and body weight for subjects in each group. Results:In group 1 subjects, area, circumference, transverse diameter, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order (γ= 0.63, 0.62, 0.61, 0.51, and 0.49; p<0.0001).In group 2 subjects, transverse diameter, circumference, area, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order (γ = 0.83, 0.82, 0.78, 0.71, and 0.71; p<0.0001).Conclusion: Cross-sectional dimensions such as area, circumference, and transverse diameter showed a higher positive correlation with image noise than body weight for pediatric low dose abdominal CT.
No takes yet. Share an insight, caveat, or question.
Jung et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: