Answers are grounded in this paper and cite their sources.
We developed a high-volume bioaerosol collection and analysis prototype device to detect low concentrations of airborne E. Coli in 50 minutes. Potential applications of this system include integration into a building’s heating, ventilation, and air conditioning system for indoor detection and identification of viral, bacterial, and fungal biological threats. A scaled-down version has potential surveillance use by the military for defense against biological weapons. Our device integrates an array of technologies including (1) the collection of airborne biological particles using a wetted wall cyclone at up to 1200 liters of air per minute, (2) microfluidic particle filtration and concentration, and (3) the extended-gate field-effect transistor (EGFET), which detects both viable and non-viable cells, as the biosensor for target pathogens. The 50-minute operation includes a 12-minute collection phase (8-minutes without recirculation, 3 minutes with recirculation, and 1 minute of residual collection without aerosol input) followed by an 8-minute concentration and a 30-minute detection phase. Using aerosolized particles containing target Escherichia coli , we detected concentrations as low as 7.6 colony-forming units (CFU) per liter of air with a sensor surface potential shift of 165 ± 73 mV.