Answers are grounded in this paper and cite their sources.
Nucleic acid detection is a cornerstone of modern molecular diagnostics, underpinning applications from disease diagnosis and pathogen surveillance to food safety and environmental monitoring. CRISPR-Cas technology has transformed nucleic acid detection by enabling highly precise, rapid and cost-effective diagnostic solutions. Systems such as SHERLOCK (Cas13-based) and DETECTR/HOLMES (Cas12-based) integrate the programmability and precision of CRISPR-Cas with the collateral cleavage activity of Cas proteins toward reporter molecules (e.g., fluorescently quenched ssDNA or RNA), yielding unprecedented levels of specificity and sensitivity for target detection.1 However, in molecular diagnostics, target nucleic acids can be present at attomolar levels, revealing a sensitivity bottleneck for direct CRISPR-based detection. Combining isothermal amplification techniques with CRISPR-based detection offers a promising solution: this integration preserves the high specificity of CRISPR while boosting sensitivity through amplification. In current CRISPR-based detection workflows, isothermal amplification and Cas-based target recognition usually remain two separate steps, requiring transfer of amplification products to a Cas-based recognition system (Figure 1A). This is operationally cumbersome and risks cross-contamination between samples.1, 2 To address these limitations, the field has increasingly shifted toward integrated “one-pot” detection systems—a paradigm that combines two or more key workflow steps (e.g., sample lysis, target amplification, and target detection) within a single, closed reaction vessel. By eliminating manual sample transfer, one-pot systems minimize cross-contamination risks, reduce hands-on time, lessen reliance on specialized equipment, and enable decentralized testing, all of which are critical for expanding global access to high-quality nucleic acid detection. To advance the performance, robustness, and practical applicability of one-pot CRISPR-based detection systems, extensive research has focused on resolving the key technical challenge of integrating amplification and Cas-based target recognition. These efforts can be broadly categorized into three complementary strategies (Figure 1B): 1. Physical separation of the amplification and nuclease steps: Physical compartmentalization isolates isothermal amplification from Cas nuclease reactions to prevent premature cross-reactivity and eliminate manual sample transfer, enabling sequential activation (amplification first, then Cas recognition). A simple approach uses a single tube with amplification reagents at the bottom and Cas reagents on the lid or inner wall. After amplification, gentle mixing initiates Cas detection. For example, opvCRISPR places RT-LAMP reagents at the bottom and Cas12a reagents on the lid, yielding a visible fluorescence readout after mixing.3 On the other hand, engineered microfluidic chips or custom devices allow more robust separation, enabling automated, sequential activation. Examples include centrifugal microfluidic systems that spatially isolate amplification and Cas13a,4 and plant-inspired suction methods that connect the two steps as amplification progresses, achieving both spatial separation and temporal control.5 However, physically separated methods that spatially separate amplification and CRISPR reagents within a single tube (e.g., in the cap or using nested tubes) or on microfluidic chips are effective but often require manual intervention (e.g., shaking, centrifugation) or complex, expensive chip fabrication, compromising true “sample-in-answer-out” simplicity and increasing costs. 2. Optimization of reaction components: A key strategy for one-pot CRISPR nucleic acid detection is reaction component optimization, which enables direct co-incubation of isothermal amplification (e.g., RPA, LAMP) and Cas systems (e.g., Cas12a, Cas13a) by resolving molecular incompatibilities. Unlike physical separation, it addresses conflicts at the molecular level. Researchers have tuned buffer compositions, enzyme ratios, and co-factor additives to create a universal reaction environment compatible with both isothermal amplification and Cas protein activity. For example, in a recent study, statistical design of experiments (DoE), specifically a definitive screening design, was used to optimize a CRISPR/Cas12a–RPA–based one-pot method,6 identifying key performance-enhancing factors such as a reverse-transcription buffer and an RNase inhibitor. Meanwhile, advanced engineering further enhances performance: template-protective Cas designs target only amplicons,7 transiently deactivated Cas proteins remain inactive during amplification,8 and suboptimal PAM site selection limits Cas activity to high-concentration amplicons.2 An illustrative case involves tuning CRISPR-Cas12a cleavage through PAM selection: suboptimal PAMs typically reduce Cas12a activity. Fu et al. showed that crRNAs designed for suboptimal PAMs can substantially enhance the efficiency and speed of one-pot detection.2 Furthermore, by optimizing the sample lysis buffer, this approach enabled an extraction-free, one-pot assay for detecting clinical samples. By resolving reagent incompatibilities at the molecular level, component optimization eliminates the need for complex physical compartmentalization. This simplifies one-pot system design, reduces manufacturing costs, and enhances assay reproducibility. 3. Phase-separation-based sequential activation: Phase-separation-based sequential activation enables one-pot CRISPR detection by spatially isolating incompatible reactions (e.g., amplification and Cas-mediated recognition) within a single vessel, leveraging the spontaneous de-mixing of multicomponent systems. Two core strategies drive this approach: (1) viscosity- and density-modifying agents (such as glycerol and agarose) slow biomolecule diffusion to prevent premature cross-reactivity, followed by gradual homogenization; (2) stimuli-responsive interfaces (such as thermoresponsive wax) create reversible barriers that can be disrupted (for example by heating) to mix the components. For instance, a one-pot CRISPR detection system optimized with glycerol9 demonstrated this principle.9 Glycerol was pre-mixed with Cas cleavage components, and its viscosity-enhancing properties maintained spatial separation from RPA (recombinase polymerase amplification) reagents. As the reaction progressed, gradual diffusion of components across the viscosity gradient eventually formed a homogeneous mixture, enabling Cas-mediated detection of amplified products. Similarly, thermoresponsive waxes have been used to regulate sequential reactions for pathogen detection.10 In this design, solid wax initially partitioned RPA reagents and CRISPR components into separate compartments. Upon heating, the wax underwent a solid-to-liquid phase transition, allowing the amplified RPA products to mix with Cas proteins and initiate target identification, all within a single closed vessel. While phase-separation-based strategies offer simplicity and efficiency for one-pot integration, their reproducibility is inherently sensitive to experimental conditions. Factors such as temperature gradients, reagent concentration ratios and the kinetics of phase transition can introduce variability in phase separation dynamics, potentially compromising assay consistency. Now CRISPR-based diagnostics promise rapid, contamination-free one-pot nucleic acid detection, but major hurdles remain. A key limitation is that many one-pot platforms do not integrate sample processing, requiring conventional extraction and hindering true sample-to-answer POCT. Future work should pursue integrated, extraction-free workflows that couple sample processing with CRISPR readouts in a single vessel. Additionally, advancing the miniaturization and portability of one-pot biosensors through innovative nanomaterials and biomolecules could enhance signal output and robustness, yielding compact, user-friendly devices with broad POCT applicability. Standardized protocols are also essential for reproducibility. Addressing these challenges is crucial to realizing CRISPR-based, one-pot detection and expanding its impact in nucleic acid diagnostics. Shuobo Shi and Yaru Li contributed to the conception and design of this manuscript. Shuobo Shi, Wenzhe Si and Yaru Li collected relevant studies for inclusion and were responsible for manuscript preparation. Qingqing Shang created the figures. Shuobo Shi and Jinyu Fu edited, critically read and revised the manuscript. All authors contributed to the article and approved the submitted version. This study was supported by Defense Industrial Technology Development Program (No. JCKY2021602B009). The authors declare no conflicts of interest. Not applicable. This work was supported by the Defense Industrial Technology Development Program (No. JCKY2021602B009).
No takes yet. Share an insight, caveat, or question.
Shi et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: