Key result
The decrease in right ventricular pulse pressure was highly reproducible across two separate episodes of ventricular tachycardia (-13 ± 2 mmHg vs -12 ± 2 mmHg; P=NS).
Why the study?
Is the measurement of right ventricular pulse pressure reproducible during separate episodes of ventricular tachyarrhythmias?
Population
10 patients undergoing a single electrophysiology study with two separate episodes of ventricular…
Comparison
Measurement of right ventricular pulse pressure… vs Measurement of right ventricular pulse pressure…
Design
Case_series
Follow-up
During a single electrophysiology study
Authors
Loading...
Reproducible RV pulse pressure drop during VT in this case; hypothesis-generating for hemodynamic sensing in ICDs.
Observational (n=10)
Is the measurement of right ventricular pulse pressure reproducible during separate episodes of ventricular tachyarrhythmias?
Absolute Event Rate: -13% vs -12%
p-value: p=NS
Right ventricular pulse pressure demonstrates short-term reproducibility during ventricular tachyarrhythmias, supporting its potential utility as a hemodynamic sensor in implantable cardioverter defibrillators.
Ellenbogen et al. (1992) conducted an observational in Ventricular Tachyarrhythmias (n=10). Right ventricular pulse pressure measurement vs. Episode 1 vs Episode 2 was evaluated on Decrease in right ventricular pulse pressure (p=NS). The decrease in right ventricular pulse pressure was highly reproducible across two separate episodes of ventricular tachycardia (-13 ± 2 mmHg vs -12 ± 2 mmHg; P=NS).