Key result
Elevated aPTT-based clot waveform analysis parameters were significantly associated with the occurrence of acute myocardial infarction, demonstrating an odds ratio of 2.06 for elevated maximum velocity (min1).
Why the study?
Elevated clot waveform analysis parameters have been associated with hypercoagulability in venous thromboembolism, but their role in arterial thrombotic disease is uncertain.
Are elevated aPTT-based clot waveform analysis (CWA) parameters associated with the occurrence of acute myocardial infarction and its complications?
Case-Control (n=323)
Yes
Are elevated aPTT-based clot waveform analysis (CWA) parameters associated with the occurrence of acute myocardial infarction and its complications?
Odds Ratio: 2.06 (95% CI 1.1–3.86)
p-value: p=0.024
Elevated aPTT-based clot waveform analysis parameters are significantly associated with the occurrence of acute myocardial infarction and its in-hospital complications, suggesting potential utility as a novel prognostic biomarker.
Suggests aPTT-based clot waveform analysis may serve as a novel.
Background: Activated partial thromboplastin time (aPTT)-based clot waveform analysis (CWA) is a plasma-based global haemostatic assay. Elevated CWA parameters have been associated with hypercoagulability in venous thromboembolism, but its role in arterial thrombotic disease is uncertain. This study aims to explore the relationship between aPTT-based CWA and acute myocardial infarction (AMI) and its complications. Methods: This is a retrospective case-control study that included patients with AMI who underwent emergency cardiac catheterisation and control patients who underwent elective orthopaedic and urological procedures. The pre-procedural aPTT and CWA parameters – min1, min2 and max2 – of AMI patients were compared against those of controls. Results: Compared to controls (N=109), patients with AMI (N=214) had shorter aPTT (26.7±3.3s vs 27.9±1.7s, P<0.001) and higher CWA parameters (min1: 6.11±1.40%/s vs 5.58±1.14%/s; min2: 0.98±0.23%/s2 vs 0.90±0.19%/s2; max2: 0.81±0.20%/s2 vs 0.74±0.16%/s2, all P≤0.001). Elevated CWA parameters, defined as having CWA values above their respective reference ranges, were associated with the occurrence of AMI, with odds ratio (OR) of 2.06 [95% confidence intervals (CI):1.10–3.86], 2.23 (95% CI:1.18–4.24) and 2.01 (95% CI:1.07–3.77) for min1, min2 and max2, respectively. Similarly, elevated min1 and min2 were both individually associated with the presence of adverse outcomes of AMI with ORs of 2.63 (95% CI:1.24–5.59). Conclusions: Patients with AMI had significantly increased CWA parameters. Elevated aPTT-based CWA parameters are significantly associated with the occurrence of AMI and its complications. Potential utility of CWA as risk and prognostic markers for AMI warrants future works.
No takes yet. Share an insight, caveat, or question.
Ng et al. (2023) conducted a case-control in Acute Myocardial Infarction (n=323). Elevated aPTT-based clot waveform analysis parameters vs. Normal clot waveform analysis parameters was evaluated on Occurrence of acute myocardial infarction (association with elevated min1) (OR 2.06, 95% CI 1.10-3.86, p=0.024). Elevated aPTT-based clot waveform analysis parameters were significantly associated with the occurrence of acute myocardial infarction, demonstrating an odds ratio of 2.06 for elevated maximum velocity (min1).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: