Key result
A geometry-based cascaded segmentation method achieved a Dice score of 0.778 on the CCA-200 dataset and 0.895 on the ASOCA dataset for coronary artery segmentation.
Why the study?
Coronary artery segmentation on CCTA is challenged by complex, tiny branches, low resolution, and poor contrast, which frequently cause vessel fragmentation in predictions.
A novel geometry-based cascaded neural network improves coronary artery segmentation and vectorization in CCTA images, avoiding fragmentations.
Demonstrates proof-of-concept for automated coronary assessment; leaves open whether this computational approach improves.
Segmentation of the coronary artery is an important task for the quantitative analysis of coronary computed tomography angiography (CCTA) images and is being stimulated by the field of deep learning. However, the complex structures with tiny and narrow branches of the coronary artery bring it a great challenge. Coupled with the medical image limitations of low resolution and poor contrast, fragmentations of segmented vessels frequently occur in the prediction. Therefore, a geometry-based cascaded segmentation method is proposed for the coronary artery, which has the following innovations: 1) Integrating geometric deformation networks, we design a cascaded network for segmenting the coronary artery and vectorizing results. The generated meshes of the coronary artery are continuous and accurate for twisted and sophisticated coronary artery structures, without fragmentations. 2) Different from mesh annotations generated by the traditional marching cube method from voxel-based labels, a finer vectorized mesh of the coronary artery is reconstructed with the regularized morphology. The novel mesh annotation benefits the geometry-based segmentation network, avoiding bifurcation adhesion and point cloud dispersion in intricate branches. 3) A dataset named CCA-200 is collected, consisting of 200 CCTA images with coronary artery disease. The ground truths of 200 cases are coronary internal diameter annotations by professional radiologists. Extensive experiments verify our method on our collected dataset CCA-200 and public ASOCA dataset, with a Dice of 0.778 on CCA-200 and 0.895 on ASOCA, showing superior results. Especially, our geometry-based model generates an accurate, intact and smooth coronary artery, devoid of any fragmentations of segmented vessels.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2024) studied Coronary artery disease (n=200). Geometry-based cascaded segmentation method was evaluated on Dice score for segmentation accuracy. A geometry-based cascaded segmentation method achieved a Dice score of 0.778 on the CCA-200 dataset and 0.895 on the ASOCA dataset for coronary artery segmentation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: