Answers are grounded in this paper and cite their sources.
The magnitude of corona point discharge current was measured in the Cornell Aeronautical Laboratory transonic wind tunnel at speeds ν in meters per second from zero to supersonic, at densities D from 0.15 to 2.1 atm, at point potentials V from 0 to ±60,000 volts. Direct currents up to 290 μa were observed. At zero speed the current is small, proportional to ion mobility, and quadratic with voltage. At high speeds the current is much greater, approximately linear with voltage and speed, and independent of polarity. Approximately 75% of 1344 data points fit the following expression for current i in amperes within 10%: In this expression ε0 = 8.854×10−12 farad/m, D0 is atmospheric density at 0°C and 760 torrs, k is ionic mobility (+1.6×10−4 or −22×10−4 m2/sec volt), and V0 is a starting potential of +6860 (D/D0)0.13 or −4940 (D/D0)0.22 volts. A slightly better fit is obtained if two additional arbitrary constants are used. From a dimensional analysis argument the coefficient 1.785 must include a geometrical dimension (to the grounded electrode or wind tunnel walls) as a term in the denominator. Therefore for a truly isolated point the first term alone applies.
No takes yet. Share an insight, caveat, or question.
Seville Chapman (1970) studied this question.