Numerical modeling demonstrates that coupled twin-forcing ventilation and coils lower roadway temperatures by 2.7–2.9 K, indicating efficient thermal management for deep mines.
To address the limited cooling range of ventilation in deep, high-temperature development headings and the lack of coordinated design between coil-based cooling and the ventilation system, this study proposes a coupled “twin-forcing–coil” cooling scheme. Building on conventional overlap (forcing–exhausting) ventilation, a rear-mounted second forcing duct is added to the conventional overlap (force–exhaust combined) auxiliary ventilation system, forming a dual-duct forcing, single-exhausting configuration—hereafter termed the “twin-forcing–single-exhausting” (TFSE) system—that provides a booster (relay) air supply to mitigate the along-path attenuation of cooling capacity and the short-circuiting of cold air; an in situ heat-exchange coil wall further provides supplementary cooling where ventilation-based temperature control weakens. Using a development heading at the 790 m level of a metal mine in Yunnan as the engineering background, a three-dimensional numerical model coupling the roadway, ventilation system, and coil wall was established and validated against nine field monitoring points, showing average relative errors of approximately 1% for temperature and 2–3% for humidity, comparable to the measurement uncertainty of the field instrumentation. Because the numerical model does not account for evaporative and condensation phase-change processes, two supplementary development headings with standing water at the face were used for validation; results showed that model error increases with water accumulation and heading length, indicating the model’s applicability is limited to conditions with intact surrounding rock and minimal seepage. Six operating cases were designed with duct placement and coil spacing as variables. Results show that single-duct ventilation cooling decays markedly beyond 30 m from the face, whereas twin-forcing booster (relay) air supply effectively extends the cooling range, reducing the 30–70 m section temperature by 2.7–2.9 K; the second duct should be positioned where the first duct’s cooling capacity begins to attenuate but is not yet depleted. Based on only two spacing configurations tested (10 m and 15 m), coil-staggered spacing showed limited effect on cooling performance under the field conditions examined; this preliminary finding requires validation across a broader range of spacings. Among the chilled-water conditions tested, an inlet temperature of 280.65 K and a flow velocity of 0.5 m/s offered a reasonable trade-off between cooling uniformity and economic efficiency. Under the boundary conditions and equipment parameters of this case, energy consumption estimates further indicate that the cooling effect per unit electricity consumption of twin-forcing ventilation is roughly 6–8 times that of coil-based cooling, primarily due to pumping losses over the ~240 m chilled-water delivery distance. This energy penalty indicates that coil-based cooling is better suited as a localized, short-distance supplementary measure rather than as a means of extending the cooling range over long distances.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: