Answers are grounded in this paper and cite their sources.
Huge signal enhancement was observed by a super-resolution near-field structure disk with a platinum-oxide layer. The carrier-to-noise ratio of 200-nm-mark trains reached 46.1 dB, and 42.3 dB was obtained even at 150-nm-mark trains. The sizes of the marks were one-fifth to one-seventh of the laser spot diameter of the readout system. The cross section of the mark trains was also observed by transmission electron microscopy. It was confirmed that 200-nm-size bubble pits were rigidly formed in good separation and ∼20-nm-platinum particles precipitated inside the bubble. The computer-simulation based on the model supported the huge signal enhancement.
No takes yet. Share an insight, caveat, or question.
Kikukawa et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: