Electric field strengths (E) from 20 to 50 kV/cm with pulse numbers ranging from 15 to 50 were applied to Bacillus spore suspensions in 0.10 to 0.15% NaCl solution. The lowest count of viable spores, expressed as the logarithmic ratio of initial count before treatment to surviving spores (log(No/N) 3.425 and 5 at 25°C) was obtained at 50 kV/cm with 30 and 50 pulses for B. subtilis and B. cereus , respectively. The log(No/N) increased with increased treatment temperature or increased time gap between pulses. Spores were unable to repair damage even after 1 mo.
No takes yet. Share an insight, caveat, or question.
MARQUEZ et al. (1997) studied this question.