Key result
Detailed Doppler reassessment resolves pseudo-pulmonary hypertension caused by an aliased aortic insufficiency jet.
Why the study?
Echocardiographic artifacts can cause significant diagnostic errors and unnecessary interventions, which is critical in pregnancy where misdiagnosing pulmonary hypertension carries serious implications.
Case Report (n=1)
No
This case report demonstrates that a medially directed diastolic aortic insufficiency jet can create an echocardiographic aliasing artifact mimicking a high-velocity systolic tricuspid regurgitation jet, underscoring the need for careful Doppler timing analysis to avoid misdiagnosing severe pulmonary hypertension and unnecessary pregnancy termination.
Answers are grounded in this paper and cite their sources.
TTE artifacts risk PH misdiagnosis in pregnancy; leaves open need for routine multimodality confirmation.
Background: Echocardiographic artifacts can lead to significant diagnostic errors, potentially resulting in unnecessary medical interventions. Accurate interpretation of echocardiographic findings is particularly critical in pregnancy, where misdiagnosis of pulmonary hypertension (PH) can have serious implications. Case presentation: We present the case of a 28-year-old pregnant woman initially diagnosed with severe PH based on transthoracic echocardiography (TTE). The high tricuspid regurgitation velocity (TRV) suggested severe PH, raising concerns about pregnancy continuation. However, a comprehensive echocardiographic reassessment identified the finding as an aliasing artifact caused by a medially directed aortic insufficiency (AI) jet. A detailed Doppler analysis revealed that the high-velocity signal obtained in the tricuspid valve region occurred during diastole rather than systole, confirming the artifact. The high-velocity flow mistakenly interpreted as a systolic tricuspid regurgitation (TR) jet was actually an aliasing of a diastolic AI jet, which was accidently parallel to the TR flow. With the correct diagnosis established, the patient was reassured and successfully carried her pregnancy to term without complications. Conclusion: This case underscores the importance of recognizing echocardiographic artifacts and pitfalls to avoid misdiagnosis. Misinterpretation of echocardiographic findings can lead to unnecessary clinical decisions, emphasizing the need for advanced echocardiographic training and careful consideration of diagnostic limitations, especially in high-risk populations.
No takes yet. Share an insight, caveat, or question.
Mirdamadi et al. (2026) conducted a case report in Suspected severe pulmonary hypertension in pregnancy (n=1). Comprehensive echocardiographic reassessment vs. Initial transthoracic echocardiography was evaluated on Accurate diagnosis of echocardiographic findings. A comprehensive echocardiographic reassessment revealed that suspected severe pulmonary hypertension was actually an aliasing artifact caused by a medially directed aortic insufficiency jet.
Synapse has enriched 10 related papers. Consider them for comparative context: