We have examined the critical current I/sub c/ and n-values of RHQT processed Nb/sub 3/Al conductors at 4.2 K in a wide range of fields from 14.5 to 25 T in relation to the microstructures obtained. For a point and a tail of Cu-clad rectangular conductor used for a winding, the n-values were determined by fitting the voltage over a taps spacing of 110 or 220 mm to a relationship of V = CI/sup n/, in a range from 10/sup -5/ to 10/sup -4/ V/m. Such n-values were almost the same with each other, indicating the uniformity of a 370 m length of RHQT Nb/sub 3/Al conductor as the I/sub c/ consistency does. The n-value increased monotonously with decreasing a field from 25 T to 18 T, but got saturated to be around 35 at 4.2 K in fields less than 18 T. The n-value at 21 T and 4.2 K, corresponding to 23.5 T and 1.8 K, was about 25, and confirmed to be large enough for NMR uses.
No takes yet. Share an insight, caveat, or question.
Takeuchi et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: