Experiments have been carried out with threshold detectors in a tissue equivalent phantom, to determine the effect of the phantom on the energy spectrum of a broad and a narrow beam of fast neutrons obtained from the M.R.C. cyclotron. The detectors were chosen with activation thresholds covering the required energy range (about 0–19 MeV), and also to give sufficient induced activity for a reasonable irradiation time. Discs of the detector materials were irradiated at various depths within the phantom, up to 30 cm. The decay curve for each was determined, and compared with that of the detectors irradiated in air. The results indicate that the beam hardens slightly at increasing depths. The spectral change is slightly greater for the narrow beam than for the broad beam, but in either case is probably insufficient to cause any significant change in R.B.E.