Why the study?
Does the PerDUCER device provide safe and effective minimally invasive access to the normal pericardium in patients undergoing cardiac surgery?
Does the PerDUCER device provide safe and effective minimally invasive access to the normal pericardium in patients undergoing cardiac surgery?
The PerDUCER device demonstrates initial feasibility and safety for minimally invasive percutaneous access to the normal pericardial space.
Answers are grounded in this paper and cite their sources.
Supports feasibility of PerDUCER access in surgical patients; leaves open need for prospective validation before wider use.
The pericardial space is being investigated as a reservoir for local drug delivery to the heart and coronary arteries. Intrapericardial drug delivery is currently limited because the pericardial space is normally small and difficult to access by standard pericardiocentesis without invasive surgery or risk of cardiac injury. Clinical trials are being conducted to evaluate a novel, minimally invasive, pericardial access device (PerDUCER, Comedicus Inc., Columbia Heights, Minn.). As of October 26, 1998, 12 clinical trials have been completed on patients undergoing cardiac surgical procedures. In all patients, a stab incision was made 1" subxiphoid and a 17G angled cannula, with preloaded guidewire, was advanced into the mediastinal space. After cannula removal, a 19F sheath/dilator was inserted over the wire. In eight patients, a median sternotomy was performed and the position of the sheath over the anterior pericardium (PC) was visually verified. Four patients underwent a closed-chest, fluoroscopy-assisted procedure. In all patients, the PerDUCER was inserted into the chest, via the sheath, and positioned over the PC. The PC was captured by suction and a bleb was formed within a side-hole on the PerDUCER tip. A sheathed needle was advanced, puncturing the isolated bleb of PC. A guidewire was advanced through the needle into the pericardial space and the PerDUCER was removed. Guidewire insertion was successful in 10 patients (7 on first attempt, 3 on second) without adverse hemodynamic effects or arrhythmia. Other than the guidewire insertion site, there was no evidence of injury to the PC or the heart. These initial clinical trials suggest that the PerDUCER may provide safe, rapid and effective percutaneous insertion of a guidewire into the normal pericardial space.
No takes yet. Share an insight, caveat, or question.
Macris et al. (1999) studied this question.