Key result
The DCNN system significantly reduced the measurement time of lower limb alignment parameters to 1.8 seconds compared to 616.8 seconds for experienced radiologists, while maintaining high consistency (ICC > 0.91).
Why the study?
A deep convolutional neural network system was proposed to measure coronal lower limb alignment parameters and the mechanical axis from radiographic images.
Does a DCNN system accurately and efficiently measure lower limb alignment parameters on standing X-rays compared to experienced radiologists?
Cross-Sectional (n=1,000)
No
Does a DCNN system accurately and efficiently measure lower limb alignment parameters on standing X-rays compared to experienced radiologists?
Absolute Event Rate: 1.8% vs 616.8%
p-value: p=<0.001
A deep convolutional neural network can automatically and accurately measure lower limb alignment parameters on X-rays significantly faster than manual measurement by radiologists.
May expedite radiographic workflows in research; leaves open clinical adoption pending prospective validation.
Background A deep convolutional neural network (DCNN) system is proposed to measure the lower limb parameters of the mechanical lateral distal femur angle (mLDFA), medial proximal tibial angle (MPTA), lateral distal tibial angle (LDTA), joint line convergence angle (JLCA), and mechanical axis of the lower limbs. Methods Standing X-rays of 1000 patients’ lower limbs were examined for the DCNN and assigned to training, validation, and test sets. A coarse-to-fine network was employed to locate 20 key landmarks on both limbs that first recognized the regions of hip, knee, and ankle, and subsequently outputted the key points in each sub-region from a full-length X-ray. Finally, information from these key landmark locations was used to calculate the above five parameters. Results The DCNN system showed high consistency (ICC > 0.91) for all five lower limb parameters. Additionally, the mean absolute error (MAE) and root mean squared error (RMSE) of all angle predictions were lower than 3° for both the left and right limbs. The MAE of the mechanical axis of the lower limbs was 1.124 mm and 1.416 mm and the RMSE was 1.032 mm and 1.321 mm, for the right and left limbs, respectively. The measurement time of the DCNN system was 1.8 ± 1.3 s, which was significantly shorter than that of experienced radiologists (616.8 ± 48.2 s, t = -180.4, P༜0.001). Conclusions The proposed DCNN system can automatically measure mLDFA, MPTA, LDTA, JLCA, and the mechanical axis of the lower limbs, thus helping physicians manage lower limb alignment accurately and efficiently.
No takes yet. Share an insight, caveat, or question.
Meng et al. (2022) conducted a cross-sectional in Patients undergoing standing X-ray examinations of the lower limbs (n=1,000). Deep convolutional neural network (DCNN) system vs. Manual measurement by experienced radiologists was evaluated on Measurement time (p=<0.001). The DCNN system significantly reduced the measurement time of lower limb alignment parameters to 1.8 seconds compared to 616.8 seconds for experienced radiologists, while maintaining high consistency (ICC > 0.91).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: