Key result
A method using time-frequency representation and wavelet denoising was proposed and tested for detecting ventricular late potentials in high-resolution electrocardiography.
A novel time-frequency representation and wavelet denoising method was developed for detecting ventricular late potentials in high-resolution ECGs.
May enhance VLP detection on HR-ECG; hypothesis-generating and requires prospective validation before clinical use.
This study proposes a method for ventricular late potentials (VLPs) detection using time-frequency representation and wavelet denoising in high-resolution electrocardiography (HRECG). The analysis is performed both with the signal averaged electrocardiography (SAECG) and in real time. A comparison between the temporal and the time-frequency analysis is also reported. In the first analysis the standard parameters QRSd, LAS40, and RMS40 were used; in the second normalized energy in time-frequency domain was calculated. The algorithm was tested adding artificial VLPs to real ECGs.
No takes yet. Share an insight, caveat, or question.
Gadaleta et al. (2012) studied Ventricular late potentials. Time-frequency representation and wavelet denoising vs. Temporal analysis (standard parameters QRSd, LAS40, and RMS40) was evaluated on Detection of ventricular late potentials. A method using time-frequency representation and wavelet denoising was proposed and tested for detecting ventricular late potentials in high-resolution electrocardiography.