Answers are grounded in this paper and cite their sources.
Many of the surgical procedures concerning the lumbar spine involve dissection of soft tissues and often removal of impinging structures.’ Such procedures may involve removal of bony architecture to allow for satisfactory decompression of the neural elements. It is often necessary to surgically fuse lumbar segments to allow for stability. Internal fixation with instrumentation often accompanies surgical fusion to augment spinal stability and enhance postoperative mobilization of the patient. However, the use of spinal fixation devices is considered somewhat controversial.2-6 The rationale for spinal fusion procedures as treatment for low back pain originates from the idea that painful symptoms caused by a degenerated or unstable spinal motion segment can be relieved.7-‘7 On the other hand, some investigators believe that spinal fusion procedures should not be encouraged because the adverse iatrogenic effects outweigh the positive results. For example, a number of investigators have noted an increase in spinal stenosis/spondylolysis, both above and below the fusion level, which they believed was caused by excessive stress on the adjacent intervertebral discs.‘6J-21 Because of these controversies, biomechanical evaluations of the various surgical procedures and various fixation systems are needed to afford a basic understanding of the issues associated with the use of internal fixation devices. A briefdescription of the biomechanical studies reported in the literature follows. An extensive bibliography is also provided for further in-depth study. three aspects: anatomical and biomechanical considerations for component design of the system,22-25 overall stability imparted to an “injured” specimen by the use of a particular instrumentation, and characterization of load-displacement behavior specifically across the stabilized segments. The results of studies concerning the overall stability characteristics of a device have shown that most of the devices currently in use are effective in restoring the stability to the injured specimens in flexion/extension, although the degree of effectiveness varies among different devices.26-29 However, these studies do not provide insights into the load-displacement behavior of the injured/stabilized levels and adjacent levels. The quantification of these parameters requires the testing of multilevel spine segments. The methodology used for preparing and testing whole lumbar spine specimens and the results obtained by the investigators are very briefly described in the following paragraphs.‘s30-33
No takes yet. Share an insight, caveat, or question.
Goel et al. (1992) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: