A monitoring system using a ring-shaped Faraday cup has been developed to observe the pulse to pulse output variation of a field emission electron source currently used in cellular radiobiological experiments performed under ultrahigh dose rate conditions. The response of the monitoring system has been calibrated against those of a conventional Faraday cup and a calorimeter. It has been shown that the monitoring system closely tracks the variations in dose absorbed by cells irradiated by individual pulses. Characteristics of the electron beam pertaining to the radlobiological experimental setup such as the mean electron energy, the stopping power (dE/dx) and the equivalent beam energy were also investigated with special attention paid to the pulse to pulse variations in their values. It has been found that the mean electron energy (~480 keV) and the equivalent energy (~100 keV) increase, while the dE/dx value for beryllium (~3.4 MeV-cm/sup 2//g) decreases with increasing beam fluence. (auth)