Key result
Fluoroscopy-guided cardiac catheterization in children was projected to yield median lifetime attributable risks of cancer ranging from 0.3 to 12.0 per 1,000 procedures.
Why the study?
What is the projected lifetime attributable risk of cancer incidence in children undergoing fluoroscopy-guided cardiac catheterization procedures?
Observational (n=1,251)
Yes
What is the projected lifetime attributable risk of cancer incidence in children undergoing fluoroscopy-guided cardiac catheterization procedures?
Fluoroscopy-guided cardiac catheterization in children is associated with a small but significant projected lifetime risk of cancer, emphasizing the importance of radiation dose optimization and long-term surveillance.
May warrant radiation minimization in pediatric cardiac catheterization; leaves open prospective validation of projected cancer risks.
Background Children treated with cardiac catheterization procedures have now a long life expectancy and consequently potential long-term radiation-induced risks. We projected lifetime attributable risks (LARs) of cancer incidence from the most frequent procedures in pediatrics: atrial septal defect closure, patent ductus arteriosus occlusion, or pulmonary valvuloplasty. Methods and Results Organ equivalent doses were estimated for 1251 procedures performed in children aged ≤15 years at 2 reference catheterization centers in France from 2009 to 2013. Sex-specific LARs were projected in lifelong nonsmokers using extended Committee on Biological Effects of Ionizing Radiation VII risk models and considering various sources of risk projection uncertainties and dose variability (Radiation Risk Assessment Tool software). Median LARs ranged between 0.3 and 1.4 (atrial septal defect closure), 0.6 and 5.0 (patent ductus arteriosus occlusion), and 1.0 and 12.0 (pulmonary valvuloplasty) per 1000 procedures, depending on patient sex and age at treatment. These radiation-related risks would represent 0.4% to 6.0% of children's total lifetime cancer risk. For the 10% of procedures (all types combined) with highest exposures, LARs reached 4.2 per 1000 (95% uncertainty interval, 0.8-13.1) in boys and 22.2 per 1000 (95% uncertainty interval, 7.4-45.6) in girls. In boys, lung cancer accounted for 70% to 80% of the projected LARs, whereas in girls it accounted for 20% to 60% and breast cancer for 30% to 80% of the excess risks, depending on the type of procedure and patient age. Conclusions Radiation exposure may lead to substantial radiation doses and increased cancer risks in some cases. This suggests the need for dose reporting to support recommendations for long-term surveillance and prevention strategies when it is necessary.
No takes yet. Share an insight, caveat, or question.
Journy et al. (2018) conducted an observational in Children treated with fluoroscopy-guided cardiac catheterization procedures (n=1,251). Fluoroscopy-guided cardiac catheterization procedures was evaluated on Lifetime attributable risks (LARs) of cancer incidence. Fluoroscopy-guided cardiac catheterization in children was projected to yield median lifetime attributable risks of cancer ranging from 0.3 to 12.0 per 1,000 procedures.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: