Key result
4D flow MRI network analysis shows coherent aortic blood flow persists over ~30% of aortic length.
Why the study?
Reductionist approaches to distilling aortic hemodynamic complexity into clinically relevant quantities cause a lossy compression of information in 4D aortic fluid structures. A network-based approach using 4D Flow MRI was proposed to characterize large-scale coherent blood motion in the healthy human aorta while reducing information loss.
How far does large-scale coherent blood motion persist along the healthy human thoracic aorta on 4D flow MRI, and is it driven by proximal ascending aorta blood flow rate dynamics or aortic geometry?
Cross-Sectional (n=41)
No
How far does large-scale coherent blood motion persist along the healthy human thoracic aorta on 4D flow MRI, and is it driven by proximal ascending aorta blood flow rate dynamics or aortic geometry?
This 4D flow MRI complex network analysis establishes normal reference values for the spatial persistence of coherent aortic blood flow in healthy humans and demonstrates that flow inertia, rather than aortic geometry, is its primary driver.
Answers are grounded in this paper and cite their sources.
Provides healthy aortic coherent flow reference values on 4D flow MRI; leaves open validation of flow inertia in disease.
Objective: The need for distilling the hemodynamic complexity into clinically relevant quantities has imposed a reductionist approach to investigate aortic flows, resulting in a lossy compression of the information hidden in 4D aortic fluid structures. Aiming at reducing information loss, this study proposes a network-based approach to identify and characterize in vivo the large-scale coherent motion of blood in the healthy human aorta using 4D Flow MRI. Methods: Adopting the quantitative paradigm of the aortic flow as a “social network”, 4D flow MRI acquisitions were performed on forty-one healthy volunteers. Correlations between the aortic blood flow rate waveform at the proximal ascending aorta (AAo), assumed as a main determinant of the aortic flow, and the waveforms of the axial velocity (aligned with the aortic centerline) in the whole aorta were used to build “one-to-all” networks. The impact of the driving flow rate waveform and of the main aortic geometric attributes on the transport of large-scale coherent fluid structures was investigated. Results: The anatomical length of persistence of large-scale coherent motion was the 29.6% of the healthy thoracic aorta length (median value, IQR 23.1%-33.9%). Moreover, it was positively correlated with the average and peak-to-peak AAo blood flow rate values, suggesting a remarkable inertial effect of the AAo flow rate on aortic hemodynamic coherence. No association emerged between the anatomical length of persistence and aortic geometric attributes. Conclusion: The here proposed in vivo approach allowed to quantitatively characterize the large-scale aortic blood motion, strengthening the definition of coherent hemodynamic structures. Significance: The findings on healthy aortas may be used as reference values to investigate the impact of aortic disease or devices implantation in disrupting/restoring the physiological spatiotemporal coherence of large-scale aortic flow.
No takes yet. Share an insight, caveat, or question.
Calò et al. (2022) conducted a cross-sectional in Healthy human thoracic aorta (tricuspid aortic valve) (n=41). 4D flow MRI 'one-to-all' complex network analysis of proximal ascending aorta blood flow rate waveform was evaluated on Anatomical length of persistence of large-scale coherent motion (Average Weighted Curvilinear Distance, AWCD) (R = 0.65 (correlation with cycle-averaged blood flow rate), p=<0.0001). In 4D flow MRI network analysis of healthy aortas, coherent flow persisted over 29.6% of aortic length and correlated with average flow rate.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: