Answers are grounded in this paper and cite their sources.
The plasma density in an expanding thermal plasma was determined using planar Langmuir probe measurements. The arc plasma was operated at low flow (500 standard cm3 per minute). It is shown that the decrease of density with increasing distance from the nozzle of the arc in an argon plasma can be explained by diffusion away from the expansion axis. The determined decay length is 10 cm. In the case that nitrogen is injected in the arc, the plasma density is lowered considerably due to charge exchange and dissociative recombination in the expansion. Because of the low electron density (1017 m−3) at a partial nitrogen flow larger than 10%, the dissociative recombination becomes slow. The main loss process of N2+ ions in this case is diffusion away from the plasma axis. The effective decay length found in the nitrogen plasma is 9 cm.
No takes yet. Share an insight, caveat, or question.
Brussaard et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: