Key result
Renal sympathetic denervation using an externally irrigated solid-tip radiofrequency ablation catheter reduced systolic/diastolic blood pressure by 57 ± 20 / 25 ± 7.5 mm Hg at 1 month.
Why the study?
Does renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter reduce blood pressure safely in patients with resistant hypertension?
Does renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter reduce blood pressure safely in patients with resistant hypertension?
Renal sympathetic denervation using an externally irrigated solid-tip RFA catheter appears safe and effectively reduces blood pressure at 1 month in patients with resistant hypertension.
Hypothesis-generating for irrigated-tip renal denervation; should not change practice in resistant hypertension without randomized data.
OBJECTIVES: This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation. BACKGROUND: RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN. METHODS: Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured. RESULTS: Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level. CONCLUSIONS: This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter.
No takes yet. Share an insight, caveat, or question.
Yalagudri et al. (2015) studied resistant hypertension (n=9). Renal sympathetic denervation using solid tip radiofrequency ablation catheter and saline irrigation was evaluated on change in systolic/diastolic blood pressure (-57 ± 20 / -25 ± 7.5 mm Hg). Renal sympathetic denervation using an externally irrigated solid-tip radiofrequency ablation catheter reduced systolic/diastolic blood pressure by 57 ± 20 / 25 ± 7.5 mm Hg at 1 month.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: