Answers are grounded in this paper and cite their sources.
As electrical capacitance tomography technique needs a sophisticated reconstruction, the accuracy of two of the most widely used reconstruction techniques (Landweber and Tikhonov) for gas‐fluidized bed applications were assessed. For this purpose, the results of two‐fluid model simulations were used as an input of reconstruction. After finding the optimum reconstruction parameters for the studied system, it is found that both techniques were able to obtain the radial profile and overall value of average volume fraction very well. Conversely, both methods were incapable to determine bubble sizes accurately especially small bubble sizes, unless the Landweber technique with inverted Maxwell concentration model is applied. The probability distribution of the reconstructed results was also smoother in transition between the emulsion and bubble phases compared to the reality. Finally, no significant differences in noise immunity of these two techniques were observed.
No takes yet. Share an insight, caveat, or question.
Banaei et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: