Key result
The right adrenal vein had significantly lower peak enhancement (247 vs 292 HU, P<0.01) and reached its peak faster (44.43 vs 45.39 seconds, P<0.01) compared to the left adrenal vein on 4D CT.
Why the study?
This study was conducted to quantitatively analyze adrenal venous flow using four-dimensional computed tomography.
Observational (n=55)
No
Absolute Event Rate: 247% vs 292%
p-value: p=<0.01
Four-dimensional CT demonstrates that the right adrenal vein has lower peak enhancement and reaches its peak faster than the left adrenal vein, with flow density influenced by BMI, plasma renin activity, and potassium.
Purpose Present study quantitatively analyzed adrenal venous flow using four-dimensional computed tomography (4D CT). Materials and Methods We reviewed 4D CT images of 55 patients [mean age, 52 years ± 11 (standard deviation); 23 females] who underwent adrenal venous sampling (AVS) between August 2017 and February 2021. Time–density curves (TDC) were referred for the adrenal venous enhancement. The clinical factors affecting hemodynamics were assessed using uni- and multivariate linear regression analyses. Results The right and left adrenal veins (RAV and LAV, respectively) were visualized in all cases. Mean peak enhancement values in RAV and LAV were 247 ± 67 and 292 ± 70 Hounsfield units (P < 0.01), and were reached at 44.43 ± 6.86 and 45.39 ± 7.53 seconds (P < 0.01), respectively. The body mass index (BMI), plasma renin activity and potassium were significant factors influencing the peak enhancement of RAV blood flow [standardized regression coefficients, -0.327 (P = 0.017), -0.346 (P = 0.013), 0.426 (P = 0.016), respectively]. A linear relationship between sex and the time-to-peak was observed for RAV [standardized regression coefficient, 0.348 (P = 0.046)]. Conclusion RAV had a lower contrast effect than LAV and reached its peak faster. BMI, plasma renin activity, and potassium were associated with flow density in RAV. Sex independently influenced the time-to-peak.
No takes yet. Share an insight, caveat, or question.
Xi et al. (2022) conducted an observational in Primary aldosteronism (n=55). Right adrenal vein (RAV) vs. Left adrenal vein (LAV) was evaluated on Peak enhancement (Dmax) (p=<0.01). The right adrenal vein had significantly lower peak enhancement (247 vs 292 HU, P<0.01) and reached its peak faster (44.43 vs 45.39 seconds, P<0.01) compared to the left adrenal vein on 4D CT.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: