Why the study?
Predicting and detecting paroxysmal atrial fibrillation at an early stage is a key priority for preventing cardioembolic complications.
Can 24-hour Holter ECG monitoring parameters predict paroxysmal atrial fibrillation in patients with sinus rhythm?
Population
97 patients with newly diagnosed paroxysmal AF and 99 matched controls
Comparison
Newly diagnosed paroxysmal AF vs matched controls without AF
Design
Single-center case-control study
Authors
Loading...
High-accuracy Holter model may support early PAF risk stratification; leaves open need for prospective validation before practice change.
Can 24-hour Holter ECG monitoring parameters predict paroxysmal atrial fibrillation in patients with sinus rhythm?
Specific 24-hour Holter ECG parameters, particularly 'P on T' early atrial extrasystoles, can highly accurately predict paroxysmal atrial fibrillation in patients with sinus rhythm.
Germanova et al. (2025) studied this question.