Electrochemical and mechanical techniques were used to grow films and study some of their properties. Polarization curve measurements were performed on Cr-Mo alloy steel specimens in carbonate/bicarbonate solutions at 75 ˚C .Films were grown at -700, -725, -750, -800 and -850 mV at 75 ˚C. It was found that stress corrosion cracking (SCC) was most likely to occur between -650 and -750 mV (SCE). AC impedance and nano- hardness of the films were measured. The results showed that the impedance of the films grown within (SCC) range had diffusion control behavior which indicated passivity whereas the impedance of the films grown outside the (SCC) range showed charge transfer behavior which meant that they were not passive. This result implies that the passive films might cause SCC in Steels. The films grown within the (SCC) range had relatively high hardness compared to those grown outside the range which indicated that the films grown within the range were brittle and might induce SCC in steels.