Answers are grounded in this paper and cite their sources.
Coalescence times are reported for bubbles of H2S and CO2 formed on adjacent nozzles in water. With CO2, times were small (1–3 ms) at pressures below 2 MPa, and rose to 20 ms at 3.4 MPa. With H2S, the logarithm of the coalescence time was proportional to pressure, and coalescence times reached 100 ms at 1.7 MPa. Film stretching rates were calculated assuming that the film surfaces were slightly immobile. By using a form of Vrij's theory for the inherent breaking time of films of constant thickness, the effective number of immobile layers could be calculated. Since these were in the range 10−2 to 10−3, only a small amount of “stiffness” in the film surface is enough to cause large changes in coalescence time.
No takes yet. Share an insight, caveat, or question.
Sagert et al. (1976) studied this question.