Multichip insulated gate bipolar transistor (mIGBT) modules are the optimal solution for achieving high current and power capacity in industrial applications. Monitoring chip open-circuit failure caused by emitter bond wire lift-off is essential for enhancing the robustness and reliability of converters. This paper proposes an in-situ monitoring method for chip open-circuit failure in mIGBT modules, which is based on the pre-charge time of gate voltage (tPG). Theoretical analysis is conducted to derive tPG as a health sensitive parameter (HSP). The sampling and diagnostic circuits are designed in detail, and the effectiveness of the proposed method is validated through double pulse and converter tests. Experimental results indicate that when chip open-circuit failure occurs, tPG significantly decreases. The proposed method is independent of bus voltage and load current, and exhibits high immunity to junction temperature variations. It requires only measuring variations in gate voltage. Furthermore, this method provides a solution for monitoring and diagnosing of chip open-circuit failure without requiring microprocessor involvement, enabling plug-and-play functionality or integration into the gate driver circuit. The proposed method presents high safety, low invasiveness, and ease of implementation.