Answers are grounded in this paper and cite their sources.
Investigations of factors influencing the starting potential and plateau slope of self-quenching G-M counters show: I. Impurities such as air or oxygen increase the plateau slope and starting potential of argon-alcohol counters. II. Operation of the counter causes changes in plateau characteristics as follows: (a) Immediately after use, the plateau slope increases slightly. (b) With continued use the plateau slope becomes steeper. (c) For moderate use the counter recovers when inactive, but never to the original characteristics. (d) With further use, the counter loses its plateau and does not recover. (e) The pressure in an argon-alcohol counter was observed to increase as a function of the total number of counts recorded. III. For argon-alcohol counters the useful life in these experiments was found to be about 10⁹-10¹⁰ counts; for argon-methane, 10⁷-10⁸ counts. The observed changes of characteristics are presumably due to the decomposition of the organic vapor by the discharge.
No takes yet. Share an insight, caveat, or question.
W. D. B. Spatz (1943) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: