Design equations for satisfying the suboptimum operating condition, i.e., only the zero-voltage switching (ZVS) condition, of a class-E amplifier with a linear shunt capacitance at any duty ratio are derived. By exploiting the suboptimum class-E operation, various amplifier parameters such as operating frequency, output power, load resistance, and component values can vary, while the ZVS operation and high efficiency can be achieved. An example of a design procedure of the class-E amplifier is given. The theoretical results were verified with PSpice simulation and an experiment.
No takes yet. Share an insight, caveat, or question.
Suetsugu et al. (2007) studied this question.