Why the study?
Does percutaneous transcatheter ASD closure acutely improve atrial and ventricular parameters assessed by cardiac MRI in patients with congenital ASD?
Does percutaneous transcatheter ASD closure acutely improve atrial and ventricular parameters assessed by cardiac MRI in patients with congenital ASD?
Cardiac MRI demonstrates significant acute reductions in right atrial size, right ventricular volume, and shunt fraction within 24 hours of transcatheter ASD closure.
Answers are grounded in this paper and cite their sources.
Acute right heart remodeling follows ASD closure; hypothesis-generating for MRI as early outcome marker but should not yet change practice.
PURPOSE: To evaluate acute changes in atrial and ventricular parameters by the use of cardiac magnetic resonance imaging (MRI) in patients with percutaneous transcatheter atrial septal defects (ASD) closure. MATERIALS AND METHODS: The study included 14 patients (six males and eight females, 45 +/- 18 years) with congenital ASD. Cardiac MRI (1.5T Philips Intera CV) was performed before and within 24 hours after transcatheter ASD closure. Right atrial (RA) and left atrial (LA) dimensions, as well as right (RV) and left (LV) ventricular end-diastolic (ED) volumes were determined. Atrial size was assessed by planimetry of the maximum RA and LA areas in a standard four-chamber view, and ventricular volumes were calculated according to a modified Simpson's rule in short-axis views. RESULTS: The mean RA decreased significantly from 27.6 +/- 6.4 cm(2) before closure to 24.4 +/- 5.6 cm(2) after the procedure (P = 0.0018), whereas the LA area did not change (24.1 +/- 4.7 cm(2) vs. 23.8 +/- 5.2 cm(2), P = 0.76). The RV volumes, volume index, and ejection fraction (EF) decreased significantly from 229 +/- 64 mL to 181 +/- 43 mL (P < 0.001, average reduction = 19% +/- 15%), from 126.0 +/- 37.2 mL/m(2) to 96.6 +/- 28.6 mL/m(2) (P < 0.0001) and from 64 +/- 5% to 58% +/- 7% (P = 0.01), respectively. The LV volumes and volume index remained unchanged (114 +/- 25 mL vs. 118 +/- 22 mL, P = 0.18, 63.5 +/- 13.5 mL/m(2) vs. 63.0 +/- 17.4 mL/m(2), P = 0.83). Left-right shunting decreased from 40% +/- 15% to 9% +/- 15% (P < 0.001). CONCLUSION: Cardiac MRI can reveal detailed information on acute changes in shunt fraction and ventricular dimensions after ASD closure. ASD closure by percutaneous transcatheter device implantation results within 24 hours in a significant reduction of shunt fraction, RA and RV sizes, and RV function, whereas LA and LV dimensions remain unchanged.
No takes yet. Share an insight, caveat, or question.
Burgstahler et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: