Why the study?
Does ultrasound imaging improve the accuracy of identifying lumbar intervertebral levels compared to palpation in patients undergoing lumbar X-ray?
Does ultrasound imaging improve the accuracy of identifying lumbar intervertebral levels compared to palpation in patients undergoing lumbar X-ray?
Ultrasound imaging is significantly more accurate than palpation for identifying lumbar intervertebral levels, reducing the risk of being more than one level off.
Answers are grounded in this paper and cite their sources.
Ultrasound may enhance lumbar level identification accuracy; leaves open whether it improves procedural outcomes in randomized settings.
The accuracy of ultrasound imaging to identify lumbar intervertebral level was assessed in 50 patients undergoing X-ray of the lumbar spine. Using an ultraviolet marker, an anaesthetist attempted to mark the L2/3, L3/4 and L4/5 intervertebral spaces. A radiologist unaware of these marks attempted to mark the same spaces with the aid of ultrasound imaging. X-ray-visible pellets were taped to the back at the various marks prior to lateral lumbar X-ray. Ultrasound imaging identified the correct level in up to 71% of cases, but palpation was successful in only 30% (p < 0.001). Up to 27% of marks using the palpation method were more than one spinal level above or below the assumed level using palpation, but none were more than one level high or low using ultrasound guidance.
No takes yet. Share an insight, caveat, or question.
Furness et al. (2002) studied this question.