Answers are grounded in this paper and cite their sources.
Breast density is an important risk factor for breast cancer development; however, imager inconsistency in density reporting can lead to patient and clinician confusion. A deep learning (DL) model for mammographic density grading was examined in a retrospective multi-reader multi-case study consisting of 928 image pairs and assessed for impact on inter- and intra-reader variability and reading time. Seven readers assigned density categories to the images, then re-read the test set aided by the model after a 4-week washout. To measure intra-reader agreement, 100 image pairs were blindly double read in both sessions. Linear Cohen Kappa (κ) and Student’s t-test were used to assess the model and reader performance. The model achieved a κ of 0.87 (95% CI: 0.84, 0.89) for four-class density assessment and a κ of 0.91 (95% CI: 0.88, 0.93) for binary non-dense/dense assessment. Superiority tests showed significant reduction in inter-reader variability (κ improved from 0.70 to 0.88, p ≤ 0.001) and intra-reader variability (κ improved from 0.83 to 0.95, p ≤ 0.01) for four-class density, and significant reduction in inter-reader variability (κ improved from 0.77 to 0.96, p ≤ 0.001) and intra-reader variability (κ improved from 0.89 to 0.97, p ≤ 0.01) for binary non-dense/dense assessment when aided by DL. The average reader mean reading time per image pair also decreased by 30%, 0.86 s (95% CI: 0.01, 1.71), with six of seven readers having reading time reductions.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: