Answers are grounded in this paper and cite their sources.
Objective: The purpose of this study is to assess the quality of platelet concentrates on storage days 1 and 5 prepared by platelet rich plasma-platelet concentrate (PRP-PC) and buffy coat poor-platelet concentrate (BC-PC) methods comparing to the American Association of Blood Banks (AABB) recommendations.Material and Method: Totally of 120 platelet concentrates (PC) units on storage days 1 and 5 (60 of PRP-PC triple blood bag and 60 of BC-PC quadruple AS-5 blood bag) were separated from whole blood donations at Songklanagarind Hospital. The prepared PC were assessed with 5 parameters such as volume, platelet count, white blood cell count per unit, pH, swirling phenomenon score and hypotonic shock response. The independent t-tests, paired Student’s t-tests and SPSS program were utilized in statistical analysis step.Results: The mean±standard deviation (S.D.) of each parameter were as follow : (1) Volume of PRP-PC and BC-PC met the standard (40-70 ml). (2) All of the platelet concentrates met the standard (≥ 5.5x1010/unit). The mean±S.D.: PRP-PC and BC-PC (day 1) were 6.820±1.480 x1010 and 7.010±1.300 x1010/unit (p-value=0.260), while PRP-PC and BC-PC (day 5) were 6.620±1.160x1010 and 6.720± 1.150x1010/unit (p-value=0.040). (3) The white blood cell in platelet concentrates met the standard (<0.2x1010/unit). The mean±S.D.: PRP-PC and BC-PC (day 1) were 0.030±0.017 x1010and 0.026±0.019x1010/unit (p-value=0.040), while PRP-PC and BC-PC (day 5) were0.033±0.013x1010 and 0.027±0.019x1010/unit (p-value= 0.580). (4) The pH of all units (PRP-PC and BC-PC) met the standard (≥6.2). The mean±S.D.: PRP-PC and BC-PC (day 1) were 7.430±0.330 and 7.750±0.160 (p-value=0.006), while PRP-PC and BC-PC (day 5) were 7.590±0.350 and 7.620±0.280 (p-value=0.710). The swirling phenomenon score and hypotonic shock response were the same as standard AABB and were not statistically difference.Conclusion: The quality of PRP-PC and BC-PC after storing on days 1 and 5 as follow (1) Volume of PRP-PC and BC-PC met the standard. (2) The platelet count per unit of PRP-PC and BC-PC (day 1), PRP-PC and BC-PC (day 5) were not statistically difference. (3) The white blood cell count per unit of PRP-PC and BC-PC (day 1) were statistically difference, while PRP-PC and BC-PC (day 5) were not statistically difference. (4) The pH of PRP-PC and BC-PC (day 1) were statistically difference, while PRP-PC and BC-PC (day 5) were not statistically difference. The swirling phenomenon score and hypotonic shock response of PRP-PC and BC-PC were not statistically difference. Platelet concentrates of both method storing on days 1 and 5 fulfilled the quality guideline of AABB.
No takes yet. Share an insight, caveat, or question.
Buathong et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: