Answers are grounded in this paper and cite their sources.
This paper proposes a new fault-tolerant strategy for a multilevel converter with an integrated impedance-source network. The proposed fault-tolerant strategy leverages the flexibility provided by the impedance-source network to implement the fundamental phase-shift compensation (FPSC) method in order to restore operation of a multilevel converter with one or more faulty switches to the prefault conditions. In case of a fault occurrence, the proposed fault-tolerant strategy makes the most use of the remaining converter capacity and generates balanced line-to-line voltages, while evenly distributing an inevitable voltage stress increase, over all converter switches. In this paper, first, a brief background about an impedance-source based cascaded H-bridge converter and a suitable modulation method for it is provided. Then, the FPSC method is explained and the proposed fault-tolerant strategy based on this method is introduced. Finally, several experimental results from a prototype converter are provided to validate the operation of the proposed strategy.
No takes yet. Share an insight, caveat, or question.
Aleenejad et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: