Answers are grounded in this paper and cite their sources.
A novel arrangement of n transformers delivers power at n times the line frequency. Ratings compare with transformers of the same weight. Waveform and voltage regulation are excellent. An experimental 7X unit with 60-cycle input gave 3.6 kw of 420-cycle output at approximately 90% efficiency. An additional 5X stage gave 2,100 cycles. Applications include high-speed a-c motors, fluorescent lighting, induction heating, control, and communication equipment.
No takes yet. Share an insight, caveat, or question.
Marvin Camras (1963) studied this question.