Answers are grounded in this paper and cite their sources.
The widths of van der Waals broadened Si I spectral lines were measured by using a conventional shock tube and a scanning Fabry-Perot interferometer. The experiments have been performed by using argon as the perturbing gas in the reflected region of the shock wave at a temperature of about 5500°K and over a pressure range of 2-10 atm. The temperature was determined by a line reversal technique; the pressure was measured using a quartz transducer. The scanning Fabry-Perot was driven by a piezoelectric crystal operating at its resonant frequency (10.5 kc/sec); the line profiles were detected photoelectrically and displayed on an oscilloscope for photographing and analyzing. A set of calculated curves was used to obtain the contribution of the pressure broadening to the widths of the spectral lines. The experimental widths thus determined are within a factor of two of the results obtained from theory.
No takes yet. Share an insight, caveat, or question.
Richard Augustus Day (1969) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: