Answers are grounded in this paper and cite their sources.
We present test results and design details for the first short-term frequency standard to achieve ultrahigh stability without the use of liquid helium. With refrigeration provided by a commercial cryocooler, the compensated sapphire oscillator (10 K CSO) makes available the superior short-term stability and phase noise performance of cryogenic oscillators without periodic interruptions for cryogen replacement. Technical features of the 10 K CSO include use of a two-stage cryocooler with vibration isolation by helium gas at atmospheric pressure, and a new sapphire/ruby resonator design giving compensated operation at 8 K to 10 K with Q=(1-2)/spl times/10/sup 9/. Stability of the first unit shows an Allan deviation of /spl sigma//sub y//spl les/2.5/spl times/10/sup -15/ for measuring times of 200 s/spl les//spl tau//spl les/600 s. We also present results showing the capability of the 10 K CSO to eliminate local oscillator degradation for atomic frequency standards. Configured as local oscillator (L.O.) for the LITS-7 trapped mercury ion frequency standard, the CSO/LITS combination demonstrated a limiting performance of 3.0/spl times/10/sup -14///spl tau//sup 1/2/, the lowest value measured to date for a passive atomic frequency standard, and virtually identical to the value calculated from photon statistics.
No takes yet. Share an insight, caveat, or question.
Wang et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: