Answers are grounded in this paper and cite their sources.
Low-level light from a multi-wavelength light source has been used to prevent late X-ray-induced dermal necrosis in the pig. Skin fields, measuring 4 cm x 4 cm on the flank, were irradiated with graded doses of X rays and the incidence of late dermal necrosis at 10-16 weeks after irradiation was scored. The control skin sites were irradiated only with 250 kV X rays but the test skin sites were subsequently exposed to low-level light. Local light exposure was from an array of gallium aluminium arsenide diodes, which produced wavelengths of 660, 820, 880 and 950 nm, pulsating at 5 kHz. Light treatment was given three times a week, from 6-16 weeks after X irradiation. Each treatment session was 1 min, which was equivalent to energy density of 1.08 Jcm-2. Light treatment increased the ED50, the dose which causes dermal necrosis in 50% of the irradiated skin fields, from 20.10 +/- 0.12 Gy to 21.94 +/- 0.30 Gy. This difference, although small, was highly significant (p < 0.001) and was equivalent to a dose modification factor (DMF) of 1.09. The effect of light treatment was minimal at incidence levels of less than the 50% but greater at higher levels of effect. These findings suggest that low-level light, when applied appropriately, may be useful in the prevention of late X-ray-induced damage to the dermis.
No takes yet. Share an insight, caveat, or question.
Rezvani et al. (1993) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: