Answers are grounded in this paper and cite their sources.
The longitudinal stress effect on magnetic properties of Si-Fe sheet materials is considered. Polish sheet materials (grain oriented ET-5 grade and non-oriented EP-20 grade) were tested. Core losses and permeability were determined using a single sheet tester with a device for exerting tensile and compressive stress. Considerable changes of specific core loss, permeability and the shape of hysteresis loop of specimens subjected to stress were observed.
No takes yet. Share an insight, caveat, or question.
Dąbrowski et al. (1989) studied this question.