Answers are grounded in this paper and cite their sources.
BACKGROUND: Testing for cerebrospinal fluid (CSF)-restricted oligoclonal bands (OCB) by isoelectric focusing is used to detect intrathecally produced total IgG. By contrast, antibody indices (AI) are assessed to test for intrathecally produced antigen-specific IgG. A number of previous cases reports have suggested that AI testing might be more sensitive than OCB testing in detecting intrathecal IgG synthesis. FINDINGS: Here we report on 21 patients with positive AI for either herpes simplex virus, varicella zoster virus, cytomegalovirus, measles virus, rubella virus, or Borrelia burgdorferi in the absence of total-IgG OCB and, accordingly, in the presence of a normal total-IgG CSF/serum ratio. CONCLUSION: Our findings indicate that AI testing should not generally be omitted in OCB-negative patients and provide a rationale for systematic and prospective studies on the comparative sensitivity and specificity of AI and total-IgG OCB testing in infectious and other diseases of the CNS.
No takes yet. Share an insight, caveat, or question.
Jarius et al. (2012) studied this question.