This paper presents a new control strategy for power factor correctors (PFCs) that are used to drive high-brightness LEDs. This control strategy is extremely simple and is based on the use of a conventional peak-current-mode controller with a suitable selection of the compensation ramp waveform. Neither an analog multiplier nor an input voltage sensor is needed to achieve quasi-sinusoidal line waveforms at nominal conditions and full load. If the converter belongs to the flyback family (flyback, buck-boost, SEPIC, Cuk and Zeta), the line waveform appears notably distorted if the compensation function is a linear ramp, but becomes almost sinusoidal if the linear ramp is substituted by a properly chosen exponential function. The line waveform is slightly distorted when the load varies or when the converter works under either overvoltage or undervoltage conditions. However, the waveform maintains a very high power factor (PF) even under these conditions. Moreover, the line current is cycle-by-cycle-controlled due to the peak-current-mode control, and hence, the input-current feedback loop is extremely fast, thereby allowing this type of control to be used with high-frequency lines (above 400 Hz)