In eddy current (EC) defect evaluation, accurate determination of the crack depth is crucial. The lift-off signal on the complex impedance plane is not necessarily horizontal and mostly arc-shaped, which makes it difficult to separate from crack signals, which can have various orientations depending on probe characteristics and frequencies. Phase rotation is normally used to align the lift-off signal to the real axis and defect signal is read from the imaginary axis . However, this approach proves challenging to separate lift-off and defect signals within the complex plane in many cases. To address this issue, this study proposes and implements a Mobius transformation that linearizes the arc-shaped lift-off signals on the complex plane, enabling more accurate extraction of crack signals unaffected by lift-off signal height. Furthermore, it is demonstrated through k-nearest neighbors (kNN) that the transformed crack signals can still be effectively quantified.
No takes yet. Share an insight, caveat, or question.
Li et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: