Performance and characteristics of a microwave source designed for the generation of overdense (Ne≥Ncr=7.4×1010 cm−3) uniform plasmas are presented. Microwave power ( f=2.45 GHz, P=20–1000 W) was introduced into the cylindrical nonresonant (for any TE and TM microwave modes) cavity (D=8.25 cm, L=22 cm) via a matched dielectric window. Two magnetic coils produced the axial static magnetic field of B≥Bce=875 G. Two plasma stream modes were observed: (i) narrow mode with a maximum plasma density on the axis, and with the magnetic field near the introduction window of B≤960 G; and (ii) wide mode with lower but uniform plasma density across the stream, and with magnetic fields near the window of 1000–1200 G. Ion current density of 7–8 mA/cm2 was typical for the narrow mode, and 4–5 mA/cm2 for the uniform mode. Ion current density relationship with gas pressure and microwave power is discussed.
No takes yet. Share an insight, caveat, or question.
Popov et al. (1992) studied this question.