Validation study demonstrates accurate automated head circumference measurement in fetal ultrasound scans, highlighting potential for standardized prenatal biometry.
Ultrasound imaging is a reliable modality in prenatal care for effective estimation of biometric parameters for fetuses to support clinical decision-making. As such, accurate detection and measurement of fetal head circumference (HC) is a commonly performed task by clinicians. However, this step is often tedious and manually extracted HCs may vary from operator to operator. Despite advances in state-of-the-art methods, achieving higher accuracy remains challenging due to the lack of publicly available large-scale datasets. This work introduces a robust end-to-end pipeline that introduces three key innovations: (1) the introduction and evaluation of the OpenFetus dataset, (2) utilizing self-supervised pre-training to extract strong feature representations on an unlabeled dataset, and (3) a fusion of two deep segmentation backbones, YOLOv12-Medium and SegFormer-B3, through a stacking ensemble meta-learner. Our proposed method reaches state-of-the-art performance on the OpenFetus dataset with Dice similarity coefficient of 97.16%, mean absolute HC error of 0.91 ± 1.32 mm, and a mean Hausdorff distance of 0.87 ± 0.69 mm, outperforming all recent baselines. This demonstrates the potential of stacking-based, self-supervised deep learning approaches for robust, reproducible, and scalable fetal biometry in real-world clinical practice.
No takes yet. Share an insight, caveat, or question.
Sarcheshmeh et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: