Why the study?
Does standardized or post-dialytic blood pressure measurement better predict left ventricular hypertrophy compared to pre-dialysis measurement in patients on hemodialysis?
Does standardized or post-dialytic blood pressure measurement better predict left ventricular hypertrophy compared to pre-dialysis measurement in patients on hemodialysis?
A single standardized blood pressure measurement predicts left ventricular hypertrophy as well as resource-intensive cumulative measurements and better than guideline-recommended pre-dialysis measurements in hemodialysis patients.
Answers are grounded in this paper and cite their sources.
Standardized post-dialytic BP may better predict LVH than pre-dialysis values in HD; leaves open whether changing measurement practice improves outcomes.
BACKGROUND: Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. METHODS: This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). RESULTS: Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. CONCLUSIONS: A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.
No takes yet. Share an insight, caveat, or question.
Khangura et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: