Answers are grounded in this paper and cite their sources.
In this paper, a new current controller that guarantees the fastest transient response is proposed. The basic concept is to find the optimal control voltage for tracking the reference current with minimum time under the voltage limit constraint. Though this minimum time control concept is also applicable to all the machine drive systems, this paper focuses on the current regulation in the three-phase pulse width modulation (PWM) converter. In the simulation and experimental results, it is observed that the proposed controller has much less transient time than the conventional synchronous PI regulator and the performance of the DC link voltage control is also greatly improved with the proposed current controller.
No takes yet. Share an insight, caveat, or question.
Chui et al. (1997) studied this question.