Key result
123I-MIBG myocardial scintigraphy delayed heart-to-mediastinum ratio accurately identified Lewy body disease with 80.0% sensitivity (95% CI 61.4-92.3) and 92.3% specificity (95% CI 74.9-99.1).
Why the study?
123I-MIBG myocardial scintigraphy is used to differentiate Lewy body diseases from similar diseases, but its diagnostic accuracy lacked validation against the gold standard of autopsy.
Does 123I-MIBG myocardial scintigraphy accurately diagnose Lewy body diseases compared to autopsy findings?
Cross-Sectional (n=56)
Does 123I-MIBG myocardial scintigraphy accurately diagnose Lewy body diseases compared to autopsy findings?
Absolute Event Rate: 80% vs 92.3%
123I-MIBG myocardial scintigraphy provides high specificity and moderate sensitivity for differentiating Lewy body diseases from similar conditions when validated against autopsy.
Abnormal 123I-MIBG supports LBD diagnosis; autopsy validation leaves open its negative predictive value amid AD comorbidity.
Background and Objectives 123I-meta-iodobenzyl-guanidine (123I-MIBG) myocardial scintigraphy is used as a diagnostic imaging test to differentiate Lewy body diseases (LBDs), including Parkinson disease and dementia with Lewy bodies, from other similar diseases. However, this imaging test lacks validation of its diagnostic accuracy against the gold standard. Our aim was to validate the diagnostic accuracy of 123I-MIBG myocardial scintigraphy for LBD against autopsy, the gold standard. Methods This retrospective, cross-sectional study included consecutive autopsy patients from the Brain Bank for Aging Research who had undergone 123I-MIBG myocardial scintigraphy. We compared the 123I-MIBG myocardial scintigraphy findings with autopsy findings. Furthermore, the proportion of residual tyrosine hydroxylase (TH)–immunoreactive sympathetic fibers in the anterior wall of the left ventricle was investigated to assess the condition of the cardiac sympathetic nerves assumed to cause reduced 123I-MIBG uptake in LBDs. Results We analyzed the data of 56 patients (30 with pathologically confirmed LBDs and 26 without LBD pathology). Compared with the neuropathologic diagnosis, the early heart-to-mediastinum (H/M) ratio had a sensitivity and specificity of 70.0% (95% CI 50.6%–85.3%) and 96.2% (95% CI 80.4%–99.9%), respectively. The delayed H/M ratio had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 92.3% (95% CI 74.9%–99.1%), respectively. The washout rate had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 84.6% (95% CI 65.1%–95.6%), respectively. The proportion of residual TH-immunoreactive cardiac sympathetic fibers strongly correlated with the amount of cardiac 123I-MIBG uptake when assessed with early and delayed H/M ratio values (correlation coefficient 0.75 and 0.81, respectively; p < 0.001). Discussion This clinicopathologic validation study revealed that 123I-MIBG myocardial scintigraphy could robustly differentiate LBDs from similar diseases. Abnormal 123I-MIBG myocardial scintigraphy findings strongly support the presence of LBD and cardiac sympathetic denervation. However, LBD pathology should not necessarily be excluded by normal myocardial scintigraphy results, especially when other biomarkers suggest the presence of comorbid Alzheimer disease pathology. Classification of Evidence This study provides Class II evidence that 123I-MIBG myocardial scintigraphy accurately identifies patients with LBD.
No takes yet. Share an insight, caveat, or question.
A 2022 study conducted a cross-sectional in Lewy body disease (n=56). 123I-MIBG myocardial scintigraphy vs. Neuropathologic diagnosis (autopsy) was evaluated on Diagnostic accuracy of delayed heart-to-mediastinum (H/M) ratio. 123I-MIBG myocardial scintigraphy delayed heart-to-mediastinum ratio accurately identified Lewy body disease with 80.0% sensitivity (95% CI 61.4-92.3) and 92.3% specificity (95% CI 74.9-99.1).