Key result
The CRAAVE assay rapidly quantified AAV genome titers with a limit of detection of 7e7 vg/mL and high precision (<3% error) compared to conventional qPCR in just 30 minutes.
Why the study?
Efficient rAAV manufacturing faces hurdles due to empty capsids and a lack of standardized analytical methods to accurately quantify viral genes and empty-to-full ratios.
The CRAAVE assay provides a rapid, amplification-free CRISPR-Cas12a method for quantifying AAV genome titers, potentially improving biomanufacturing process analytical technology.
CRISPR-Dx may standardize rAAV empty-to-full quantification; leaves open impact on clinical manufacturing scalability.
Efficient manufacturing of recombinant Adeno-Associated Viral (rAAV) vectors to meet rising clinical demand remains a major hurdle. One of the most significant challenges is the generation of large amounts of empty capsids without the therapeutic genome. There is no standardized analytical method to accurately quantify the viral genes, and subsequently the empty-to-full ratio, making the manufacturing challenges even more complex. We propose the use of CRISPR diagnostics (CRISPR-Dx) as a robust and rapid approach to determine AAV genome titers. We designed and developed the CRISPR-AAV Evaluation (CRAAVE) assay to maximize sensitivity, minimize time-to-result, and provide a potentially universal design for quantifying multiple transgene constructs encapsidated within different AAV serotypes. We also demonstrate an on-chip CRAAVE assay with lyophilized reagents to minimize end user assay input. The CRAAVE assay was able to detect AAV titers as low as 7e7 vg/mL with high precision (<3% error) in quantifying unknown AAV titers when compared with conventional quantitative PCR (qPCR) method. The assay only requires 30 minutes of assay time, shortening the analytical workflow drastically. Our results suggest CRISPR-Dx could be a promising tool for efficient rAAV genome titer quantification and has the potential to revolutionize biomanufacturing process analytical technology (PAT).
No takes yet. Share an insight, caveat, or question.
Hetzler et al. (2023) studied AAV vector manufacturing. CRAAVE assay (CRISPR-Cas12a) vs. qPCR was evaluated on Limit of detection and quantification accuracy of AAV genome titers. The CRAAVE assay rapidly quantified AAV genome titers with a limit of detection of 7e7 vg/mL and high precision (<3% error) compared to conventional qPCR in just 30 minutes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: