Answers are grounded in this paper and cite their sources.
In digitally controlled dc–dc converters with a single voltage feedback loop, the two quantizers, namely the analog-to-digital (A/D) converter and the digital pulse-width modulator (DPWM), can cause undesirable limit-cycle oscillations. In this paper, static and dynamic models that include the quantization effects are derived and used to explain the origins of limit-cycle oscillations. In the static model, existence of dc solution, which is a necessary no-limit-cycle condition, is examined using a graphical method. Based on the generalized describing function method, the amplitude and offset-dependent gain model of a quantizer is applied to derive the dynamic system model. From the static and dynamic models, no-limit-cycle conditions associated with A/D, DPWM and compensator design criteria are derived. The conclusions are illustrated by simulation and experimental examples.
No takes yet. Share an insight, caveat, or question.
Hao et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: